<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>[AP Network 인증원-해외 제품 시험인증 상담 &#124; ASTM &#124; MIL-STD-810 &#124; 자동차 OEM 규격시험 &#124; DIN &#124; EN, GOST-R &#124; TEST &#38; CERTIFICATE &#124; &#187; membrane</title>
	<atom:link href="http://www.anycerti.com/tag/membrane/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.anycerti.com</link>
	<description>[제품 시험 인증] ASTM, MIL-STD-810, CE Mark, TR CU, EN, DIN, GOST, 시험, 인증 컨설팅</description>
	<lastBuildDate>Sun, 27 Jul 2025 11:13:05 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.6.1</generator>
		<item>
		<title>ASTM D6878 &#8211; on TPO membrane Analysis</title>
		<link>http://www.anycerti.com/astm-d6878-on-tpo-membrane-analysis/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=astm-d6878-on-tpo-membrane-analysis</link>
		<comments>http://www.anycerti.com/astm-d6878-on-tpo-membrane-analysis/#comments</comments>
		<pubDate>Fri, 05 Dec 2014 01:54:32 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Anycerti.com - BLOG]]></category>
		<category><![CDATA[ASTM Test]]></category>
		<category><![CDATA[CE Marking]]></category>
		<category><![CDATA[EN Norm & DIN]]></category>
		<category><![CDATA[GOST-R]]></category>
		<category><![CDATA[MIL-Spec & STD]]></category>
		<category><![CDATA[News & Stuff]]></category>
		<category><![CDATA[astm]]></category>
		<category><![CDATA[astm d]]></category>
		<category><![CDATA[astm d6878]]></category>
		<category><![CDATA[membrane]]></category>

		<guid isPermaLink="false">http://www.anycerti.com/?p=6052</guid>
		<description><![CDATA[건축자재 인증 및 시험 관련 규격 Download : Analysis of one TPO membrane per ASTM D6878_D6878M-13 Analysis of one TPO membrane per ASTM D6878/D6878M-13. 아래는 적용되는 분석기법입니다. ASTM D 6878/D : Brittleness Point per ASTM D2137, Method B ASTM D 6878/D : Ozone Resistance per ASTM D 1149 (Exposed to 100 mPa ozone in air @40°C, [&#8230;]]]></description>
				<content:encoded><![CDATA[<p><span style="color: #ff6600;"><strong>건축자재 인증 및 시험 관련 규격</strong></span></p>
<p style="text-align: right;">Download : <a href="http://www.anycerti.com/wp-content/uploads/2014/12/Analysis-of-one-TPO-membrane-per-ASTM-D6878_D6878M-13.pdf">Analysis of one TPO membrane per ASTM D6878_D6878M-13</a></p>
<p style="text-align: left;"><span style="font-size: 13px;">Analysis of one TPO membrane per ASTM D6878/D6878M-13.</span></p>
<p style="text-align: left;">아래는 적용되는 분석기법입니다.</p>
<ol>
<ol>
<li>ASTM D 6878/D : Brittleness Point per ASTM D2137, Method B</li>
<li>ASTM D 6878/D : Ozone Resistance per ASTM D 1149 (Exposed to 100 mPa ozone in air @40°C, wrapped around a 3&#8243; mandrel for 166 hrs exposure) &#8211; OUTSOURCED</li>
<li>ASTM D 6878/D : Breaking Strength per ASTM D751, grab method &#8211; MD</li>
<li>ASTM D 6878/D : Breaking Strength per ASTM D751, grab method &#8211; XMD</li>
<li>ASTM D 6878/D : Elongation at Reinforcement Break per ASTM D751, grab method &#8211; MD</li>
<li>ASTM D 6878/D : Elongation at Reinforcement Break per ASTM D751, grab method &#8211; XMD</li>
<li>ASTM D 6878/D : Factory Seam Strength @ 2 in/min (12 in x 1 in specimen) per ASTM D751,grab method</li>
<li>ASTM D 6878/D : Heat Aging, 5376 hrs (224 days) @ 116°C, per ASTM D573</li>
<li>ASTM D 6878/D : Linear Dimensional Change, 6 hr @ 70°C (158°F), per ASTM D1204</li>
<li>ASTM D 6878/D : Post Heat Aging: Breaking Strength per ASTM D751, grab method &#8211; MD</li>
<li>ASTM D 6878/D : Post Heat Aging: Breaking Strength per ASTM D751, grab method &#8211; XMD</li>
<li>ASTM D 6878/D : Post Heat Aging: Elongation at Reinforcement Break per ASTM D751, grab method &#8211; MD</li>
<li>ASTM D 6878/D : Post Heat Aging: Elongation at Reinforcement Break per ASTM D751, grab method &#8211; XMD</li>
<li>ASTM D 6878/D : Post Heat Aging: Tearing Strength, 2 in/min (8 in x 8 in specimen) per ASTMD751 &#8211; MD</li>
<li>ASTM D 6878/D : Post Heat Aging: Tearing Strength, 2 in/min (8 in x 8 in specimen) per ASTMD751 &#8211; XMD</li>
<li>ASTM D 6878/D : Post Heat Aging: Weight Change (mass)</li>
<li>ASTM D 6878/D : Tearing Strength, 2 in/min (8 in x 8 in specimen), per ASTM D751 &#8211; MD</li>
<li>ASTM D 6878/D : Tearing Strength, 2 in/min (8 in x 8 in specimen), per ASTM D751 &#8211; XMD</li>
<li>ASTM D 6878/D : Thickness, Coating Over Fabric or Scrim (weathering side only) per ASTM D7635</li>
<li>ASTM D 6878/D : Thickness, Sheet-Overall per ASTM D751</li>
<li>ASTM D 6878/D : Water Absorption, 166 hrs @ 70°C (158°F) (mass) per ASTM D471 – Performed on top coating material ONLY</li>
<li>ASTM D 6878/D : Weather Resistance per ASTM G 155 at 0.35 W/(m²•nm) at 340 nm (8000 hrs)</li>
</ol>